SIP SERVER UCM6202
- Connect using a browser (Google Chrome, IE, etc.)
- Click “Continue to the site”
- Login: admin
- Password: Conduent01
Change IP Address
- Go to System Settings / Network Settings
Example Configuration
- Chief terminal: extension 1000
- BSM2: extension 1002
- BSM4: extension 1004
Creating an Extension
- Click the "edit" button next to extension 1001
- Set a password (e.g., E1001) – this will be used when configuring the ET908SIP
- Go to the Function tab if you want to enable call forwarding
- Select “Custom number” if forwarding to a phone number
- Select “Extension” if forwarding to another chief terminal
- Click Save once configuration is complete
- Repeat for all necessary extensions (usually just the one receiving calls)

Verify Analog Trunk Presence

Setting Up Call Forwarding (if no answer)
- Go to Outgoing Routes, click Edit
- Prefix the phone number with an underscore ( _ )

Forward All Calls Based on Time of Day
- Configure Office Hours
- Then configure the concerned extension (e.g., chief terminal)
- Create a second outgoing route using the desired forwarding number
- Example:
- - Between 10:35 and 17:30, equipment calls extension 1000
- - If unanswered → forwards to 014132xxxx
- - Outside office hours → directly calls 061199xxxx

Final Steps
- Click Apply when all settings are complete
- Reboot the device
- Don’t forget to plug the telephone line into the Fx01 port on the GrandStream

ET908 SIP Configuration
- Change IP address via IPconfig
- Access via browser
- Login: admin
- Password: SIPstation93400!

SIP Settings
- User ID = extension number
- Authentication = extension number
- Password = password set for the GrandStream extension
- Proxy = SIP server (GrandStream address); default is E + extension number (e.g., E1001)
- If no SIP server:
- - Uncheck Registration enabled
- - Remove Proxy
- - (Used in configurations with only ET908 and EE980 chief terminal)

Phonebook Menu
- Click Add
- Direct Call Button → select “button 0”
- Destination = chief terminal number
Relay Output Settings
- Click Apply
- Go to System → System Settings → Reboot

Chief Terminal EE980 Configuration
- Connect via browser
- Login: admin
- Password: commend

IP Address Change
- As needed

SIP Menu
- Enter password set in GrandStream for extension 1000 (default: E + extension number, e.g., E1000)

Phonebook
- Add all your devices
- Click Apply to save